Part Number: 414-00005-08 | Manufacturer: Sensata Technologies Inc | NSN: 5925-01-322-2046 (5925013222046) |
Item Name : Circuit Breaker | CAGE Code: 81541 | FSC: 5925 Circuit Breakers |
Alternate P/N : 4140000508 |
The NSN Part 414-00005-08 Circuit Breaker. is ready-to-ship today! Please request a quote by filling out the form. All fields are important. The NSN number for 414-00005-08 is 5925013222046. The manufacturer of this part is Sensata Technologies Inc. A dedicated customer service executive will contact you within 15 minutes of receiving the RFQ.
Note : We will not share your information to any third parties.
“*” Symbols for mandatory fields
BuyNSN.com is an ASAP Semiconductor website. We are an industry leading distributor of National Stock Number (NSN) parts. We provide 50 million parts from over 10,000 manufacturers. These stock numbers are organized under 46 federal supply groups. We have an unwavering commitment to quality, fastest shipping times in the industry, strict adherence to export compliance protocol, and competitive prices.
Your RFQ for 414-00005-08 part will be answered by a dedicated sales representative. Do you think 15 minutes is a long time? Please feel free to call us on +1-714-705-4780 24/7 or email your Bill of Materials (BOM) to sales@buynsn.com. For regular updates and hot offers on NSN numbers and other part numbers, please download ASAP Semiconductor App from Google Play Store or App Store.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-322-2046 Item PartTypeName: CIRCUIT BREAKER | 5925 | 013222046 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
414-00005-08 | 5 | 2 | 1 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC SECOND LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CQJX | NOMINAL THREAD SIZE | 0.134 INCHES |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | VIBRATION RESISTANT AND SHOCK RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF |
TTQY | TERMINAL TYPE AND QUANTITY | 8 THREADED STUD |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.920 INCHES MINIMUM AND 1.960 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
AJEC | BOSS HEIGHT | 0.135 INCHES MINIMUM AND 0.165 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.444 INCHES MINIMUM AND 2.506 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
ADAQ | BODY LENGTH | 2.500 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC SECOND LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 65.0 DC FIRST LOCATION |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CQQC | TRIP RELEASE DUTY CYCLE | CONTINUOUS ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.180 MINIMUM AT 200 PCT AND 1.800 MAXIMUM AT 200 PCT SECOND LOCATION |
FREQ | FREQUENCY IN HERTZ | 60.0 SECOND LOCATION |
AAJE | THREAD PITCH DIAMETERS | 0.1177 TO 0.1214 INCHES |
ADAT | BODY WIDTH | 1.515 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 2 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 35.0 AMPERES DC FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SECOND LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 DC FIRST LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRK | AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS | 25.0 DC NOMINAL ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES/RELAY TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.700 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT FIRST LOCATION |
CWJK | CASE MATERIAL | PLASTIC |
THSD | THREAD SERIES DESIGNATOR | UNC |
ZZZK | SPECIFICATION/STANDARD DATA | 95266-414-00005-08 MANUFACTURERS SOURCE CONTROL |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote