Alternative NSN: 6210-01-509-1841 |
Item Name:Light Indicator |
FSG: 62 Lighting Fixtures and Lamps |
Federal Supply Class (FSC): 6210 Indoor and Outdoor Electrical lighting Fixtures |
NIIN: 015091841 |
NCB Code: USA (01) |
Manufacturers: Drs Power And Control Technologies |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
6962ED3497 PIECE 31 | Drs Power And Control Technologies | light indicator | Avl | RFQ |
6981ED166-1578 | Drs Power And Control Technologies | light indicator | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.630 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.750 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.120 INCHES NOMINAL |
AEUJ | LAMP BASE TYPE ACCOMMODATED | MIDGET SCREW |
AEWU | LAMP BULB SIZE DESIGNATOR | T-1 3/4 |
AEXC | LENS QUANTITY | 1 |
AEXD | LENS COLOR | RED SINGLE ROW 1ST POSITION HORIZONTAL |
AFAX | LAMP INDUSTRY NUMBER | 1769 |
AGAV | END ITEM IDENTIFICATION | CONTROLLER |
AXGY | MOUNTING METHOD | BRACKET AND FLUSH |
CRHX | LAMP TYPE ACCOMMODATED AND QUANTITY | 2 INCANDESCENT |
CTCB | LENS LEGEND | HEAD 1ST ROW 1ST POSITION HORIZONTAL FULL DISPLAY DIVISION A |
CTCB | LENS LEGEND | LOW LEVEL 3RD ROW 1ST POSITION HORIZONTAL FULL DISPLAY DIVISION A |
CTCB | LENS LEGEND | TANK 2ND ROW 1ST POSITION HORIZONTAL FULL DISPLAY DIVISION A |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | INDICATING LIGHT STATION, FLUSH MOUNTED |
FEAT | SPECIAL FEATURES | RSTATION INCLUDES 1 ELEMENT A 117V, 60HZ 86-2469-3; 2 LAMPS 28-651; 2 BRACKETS 79-6389; 1 GASKET 32-580; 1 LENS 28-822; 1 LEGEND PLATE 30-3690; 1 INSULATOR 56-3669; 2 TERMINAL SCREWS 11-1627; 2 HELICAL WASHERS 916-4027 |
MATT | MATERIAL | PLASTIC LENS |
STYL | STYLE DESIGNATOR | RECTANGULAR FRAME TYPE |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-2212 GOVERNMENT SPECIFICATION AND 96906-MS-15612-3 GOVERNMENT STANDARD |
ABHP | OVERALL LENGTH | 2.630 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.750 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.120 INCHES NOMINAL |
AEUJ | LAMP BASE TYPE ACCOMMODATED | MIDGET SCREW |
AEWU | LAMP BULB SIZE DESIGNATOR | T-1 3/4 |
AEXC | LENS QUANTITY | 1 |
AEXD | LENS COLOR | RED SINGLE ROW 1ST POSITION HORIZONTAL |
AFAX | LAMP INDUSTRY NUMBER | 1769 |
AGAV | END ITEM IDENTIFICATION | CONTROLLER |
AXGY | MOUNTING METHOD | BRACKET AND FLUSH |
CRHX | LAMP TYPE ACCOMMODATED AND QUANTITY | 2 INCANDESCENT |
CTCB | LENS LEGEND | HEAD 1ST ROW 1ST POSITION HORIZONTAL FULL DISPLAY DIVISION A |
CTCB | LENS LEGEND | LOW LEVEL 3RD ROW 1ST POSITION HORIZONTAL FULL DISPLAY DIVISION A |
CTCB | LENS LEGEND | TANK 2ND ROW 1ST POSITION HORIZONTAL FULL DISPLAY DIVISION A |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | INDICATING LIGHT STATION, FLUSH MOUNTED |
FEAT | SPECIAL FEATURES | RSTATION INCLUDES 1 ELEMENT A 117V, 60HZ 86-2469-3; 2 LAMPS 28-651; 2 BRACKETS 79-6389; 1 GASKET 32-580; 1 LENS 28-822; 1 LEGEND PLATE 30-3690; 1 INSULATOR 56-3669; 2 TERMINAL SCREWS 11-1627; 2 HELICAL WASHERS 916-4027 |
MATT | MATERIAL | PLASTIC LENS |
STYL | STYLE DESIGNATOR | RECTANGULAR FRAME TYPE |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-2212 GOVERNMENT SPECIFICATION AND 96906-MS-15612-3 GOVERNMENT STANDARD |
6210-00-001-1425 (6210000011425) |
6210-00-001-1426 (6210000011426) |
6210-00-001-1430 (6210000011430) |
6210-00-001-1431 (6210000011431) |
6210-00-001-1438 (6210000011438) |
6210-00-001-1440 (6210000011440) |
6210-00-001-1441 (6210000011441) |
6210-00-001-1446 (6210000011446) |
6210-00-001-1447 (6210000011447) |
6210-00-001-1448 (6210000011448) |
6210-00-001-1453 (6210000011453) |
6210-00-001-1455 (6210000011455) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote