Alternative NSN: 6130-01-195-9763 |
Item Name:Power Supply |
FSG: 61 Electric Wire and Power and Distribution Equipment |
Federal Supply Class (FSC): 6130 Converters Electrical Nonrotating |
NIIN: 011959763 |
NCB Code: USA (01) |
Manufacturers: Edo Corp , Arnold Magnetics Corporation |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
508702 | Edo Corp | power supply | Avl | RFQ |
508702 | Arnold Magnetics Corporation | power supply | Avl | RFQ |
508702-1 | Arnold Magnetics Corporation | power supply | Avl | RFQ |
508702-1 | Edo Corp | power supply | Avl | RFQ |
NH-3127 | Edo Corp | power supply | Avl | RFQ |
NH-3127 | Arnold Magnetics Corporation | power supply | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 10.500 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 4.063 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.625 INCHES MAXIMUM |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APNX | INPUT VOLTAGE RATING | 22.0 DC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 26.0 DC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
AYNH | OPERATING AMBIENT TEMP RANGE | -10.0/71.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 3RD POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 3RD POWER OUTPUT |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | 10.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 2.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 2.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 3RD POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | SOLDER STUD SINGLE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 2 SINGLE OPERATING POWER RQMT |
6105-00-001-1710 (6105000011710) |
6105-00-001-1712 (6105000011712) |
6105-00-001-3680 (6105000013680) |
6105-00-001-4309 (6105000014309) |
6105-00-001-4477 (6105000014477) |
6105-00-001-5214 (6105000015214) |
6105-00-001-5532 (6105000015532) |
6105-00-001-5533 (6105000015533) |
6105-00-001-6460 (6105000016460) |
6105-00-001-6807 (6105000016807) |
6105-00-001-8051 (6105000018051) |
6105-00-001-8980 (6105000018980) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote