Alternative NSN: 5955-01-447-9140 |
Item Name:Oscillator Noncryst |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5955 Oscillators Piezoelectric Crystals |
NIIN: 014479140 |
NCB Code: USA (01) |
Manufacturers: Microsource Corp , The Boeing Company |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
4000-41005-03 | Microsource Corp | oscillator noncryst | Avl | RFQ |
4000-41005-03 | The Boeing Company | oscillator noncryst | Avl | RFQ |
MSO-0818-309-01 | The Boeing Company | oscillator noncryst | Avl | RFQ |
MSO-0818-309-01 | Microsource Corp | oscillator noncryst | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.400 INCHES NOMINAL" |
ADAV | OVERALL DIAMETER | 2.000 INCHES NOMINAL" |
AFGA | OPERATING TEMP RANGE | -54.0/+85.0 DEG CELSIUS" |
AFSU | AVERAGE LIFE MEASUREMENT | NOT RATED" |
AGAV | END ITEM IDENTIFICATION | E-3 ESM GRP B, CAGE 32562" |
AGTA | BASIC SHAPE STYLE | CYLINDRICAL" |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 30000.0 FEET" |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED" |
ALBM | OPERATING CONTROL METHOD | AUTOMATIC" |
AMQY | INSTALLATION DESIGN | MECHANICAL" |
AQZF | CONTROL TYPE | REMOTE" |
BHSX | III CIRCUIT CONSTRUCTION TYPE | SOLID STATE" |
BHTB | FREQUENCY PER CHANNEL | 8.0 GIGAHERTZ MINIMUM OPERATING CHANNEL AND 18.0 GIGAHERTZ MAXIMUM OPERATING CHANNEL" |
BJBP | CONNECTION TYPE AND LOCATION | PIN BOTTOM AND RECEPTACLE, COAXIAL BOTTOM" |
BJBW | CONNECTION CONTACT TYPE AND QUANTITY | 8 PIN EXTERNAL AND 1 RECEPTACLE, COAXIAL EXTERNAL" |
BKFB | EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 14.8 MINIMUM SINGLE VOLTAGE AND 15.2 MAXIMUM SINGLE VOLTAGE" |
TEST | TEST DATA DOCUMENT | 32562-4000-41005 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING D" |
ZZZK | SPECIFICATION/STANDARD DATA | 32562-4000-41005-01 MANUFACTURERS SPECIFICATION" |
ABHP | OVERALL LENGTH | 1.400 INCHES NOMINAL" |
ADAV | OVERALL DIAMETER | 2.000 INCHES NOMINAL" |
AFGA | OPERATING TEMP RANGE | -54.0/+85.0 DEG CELSIUS" |
AFSU | AVERAGE LIFE MEASUREMENT | NOT RATED" |
AGAV | END ITEM IDENTIFICATION | E-3 ESM GRP B, CAGE 32562" |
AGTA | BASIC SHAPE STYLE | CYLINDRICAL" |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 30000.0 FEET" |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED" |
ALBM | OPERATING CONTROL METHOD | AUTOMATIC" |
AMQY | INSTALLATION DESIGN | MECHANICAL" |
AQZF | CONTROL TYPE | REMOTE" |
BHSX | III CIRCUIT CONSTRUCTION TYPE | SOLID STATE" |
BHTB | FREQUENCY PER CHANNEL | 8.0 GIGAHERTZ MINIMUM OPERATING CHANNEL AND 18.0 GIGAHERTZ MAXIMUM OPERATING CHANNEL" |
BJBP | CONNECTION TYPE AND LOCATION | PIN BOTTOM AND RECEPTACLE, COAXIAL BOTTOM" |
BJBW | CONNECTION CONTACT TYPE AND QUANTITY | 8 PIN EXTERNAL AND 1 RECEPTACLE, COAXIAL EXTERNAL" |
BKFB | EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 14.8 MINIMUM SINGLE VOLTAGE AND 15.2 MAXIMUM SINGLE VOLTAGE" |
TEST | TEST DATA DOCUMENT | 32562-4000-41005 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING D" |
ZZZK | SPECIFICATION/STANDARD DATA | 32562-4000-41005-01 MANUFACTURERS SPECIFICATION" |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote