Alternative NSN: 5950-00-510-1672 |
Item Name:Transformer Power |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 005101672 |
NCB Code: USA (00) |
Manufacturers: Te Connectivity Networks Inc , Pax Mfg Corp , Magnetic Components Inc , Emerson Electric Co , Freed Transformer Company , North Erie Electronics Inc , Buckles International Inc , National Aerospace Standards , Military Specifications Promulgated By Military Departments/Agencies Under Autho |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
1500-0163 | Te Connectivity Networks Inc | transformer power | Avl | RFQ |
1500-0163 | Pax Mfg Corp | transformer power | Avl | RFQ |
1500-0163 | Magnetic Components Inc | transformer power | Avl | RFQ |
20164-2 | Emerson Electric Co | transformer power | Avl | RFQ |
27719 | Freed Transformer Company | transformer power | Avl | RFQ |
30-7296 | Magnetic Components Inc | transformer power | Avl | RFQ |
30-7296 | Pax Mfg Corp | transformer power | Avl | RFQ |
30-7296 | Te Connectivity Networks Inc | transformer power | Avl | RFQ |
59T11C1336 | Te Connectivity Networks Inc | transformer power | Avl | RFQ |
59T11C1336 | North Erie Electronics Inc | transformer power | Avl | RFQ |
59T11C1336 | Pax Mfg Corp | transformer power | Avl | RFQ |
59T11C1336 | Magnetic Components Inc | transformer power | Avl | RFQ |
A15055 | Pax Mfg Corp | transformer power | Avl | RFQ |
A15055 | Te Connectivity Networks Inc | transformer power | Avl | RFQ |
A15055 | Magnetic Components Inc | transformer power | Avl | RFQ |
SMC248798 | Magnetic Components Inc | transformer power | Avl | RFQ |
SMC248798 | Buckles International Inc | transformer power | Avl | RFQ |
SMC248798 | North Erie Electronics Inc | transformer power | Avl | RFQ |
TF1SX03YY | Te Connectivity Networks Inc | transformer power | Avl | RFQ |
TF1SX03YY | Pax Mfg Corp | transformer power | Avl | RFQ |
TF1SX03YY | National Aerospace Standards | transformer power | Avl | RFQ |
TF1SX03YY | Military Specifications Promulgated By Military Departments/Agencies Under Autho | transformer power | Avl | RFQ |
TF1SX03YY | Magnetic Components Inc | transformer power | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.063 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP5.063 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 62.0 HERTZ NOMINAL SINGLE COMPONENT62.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 6.000 INCHES NOMINAL6.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 5.594 INCHES NOMINAL5.594 INCHES NOMINAL |
ADAU | BODY HEIGHT | 4.625 INCHES NOMINAL4.625 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALEDHERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 6 SINGLE GROUP6 SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT3 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP32 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
CQLC | UNABLE TO DECODE | UNABLE TO DECODE |
CRBZ | WINDING OPERATING CURRENT | 1.2 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 8.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY570.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 25.20 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 570.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY25.20 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 12 TAB,SOLDER LUG |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote