Alternative NSN: 5950-00-324-0267 |
Item Name:Transformer Power |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 003240267 |
NCB Code: USA (00) |
Manufacturers: Sora Power Inc , Raytheon Company , Oeco Corp , Standard Industries |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
11570 | Sora Power Inc | transformer power | Avl | RFQ |
11570 | Raytheon Company | transformer power | Avl | RFQ |
11570 | Oeco Corp | transformer power | Avl | RFQ |
310-18311-01 | Oeco Corp | transformer power | Avl | RFQ |
310-18311-01 | Raytheon Company | transformer power | Avl | RFQ |
310-18311-01 | Sora Power Inc | transformer power | Avl | RFQ |
860923 | Raytheon Company | transformer power | Avl | RFQ |
860923 | Oeco Corp | transformer power | Avl | RFQ |
860923 | Sora Power Inc | transformer power | Avl | RFQ |
860923 | Standard Industries | transformer power | Avl | RFQ |
984717-2B | Standard Industries | transformer power | Avl | RFQ |
984717-2B | Sora Power Inc | transformer power | Avl | RFQ |
984717-2B | Raytheon Company | transformer power | Avl | RFQ |
984717-2B | Oeco Corp | transformer power | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3.000 INCHES MAXIMUM3.000 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 3.000 INCHES MAXIMUM3.000 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.380 INCHES NOMINAL SINGLE GROUP0.380 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 15.0 KILOHERTZ NOMINAL SINGLE COMPONENT15.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAU | BODY HEIGHT | 1.780 INCHES MAXIMUM1.780 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT7 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 10.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 12.0 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY10.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY10.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 134.33 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY134.33 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 28.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY28.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 4.24 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY4.24 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | THIRD AND FOURTH SECONDARIES HAVE THE CURRENT AND VOLTAGE RECTIFIED; ALSO THE TRANSFORMER CONSIST OF ONE PRIMARY AND SEVEN SECONDARY WINDINGSTHIRD AND FOURTH SECONDARIES HAVE THE CURRENT AND VOLTAGE RECTIFIED; ALSO THE TRANSFORMER CONSIST O |
PKWT | UNABLE TO DECODE | UNABLE TO DECODE |
TTQY | TERMINAL TYPE AND QUANTITY | 24 TAB,SOLDER LUG |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote