Alternative NSN: 5945-01-365-1230 |
Item Name:Relay Electromagnet |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5945 Relays and Solenoids |
NIIN: 013651230 |
NCB Code: USA (01) |
Manufacturers: Tyco Electronics Corp , Howden Fluid Systems , Hi G Co Inc |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
324252P1 | Tyco Electronics Corp | relay electromagnet | Avl | RFQ |
324252P1 | Howden Fluid Systems | relay electromagnet | Avl | RFQ |
324252P1 | Hi G Co Inc | relay electromagnet | Avl | RFQ |
HFW1131K05M | Hi G Co Inc | relay electromagnet | Avl | RFQ |
HFW1131K05M | Tyco Electronics Corp | relay electromagnet | Avl | RFQ |
HFW1131K05M | Howden Fluid Systems | relay electromagnet | Avl | RFQ |
J2K-4730-207M | Tyco Electronics Corp | relay electromagnet | Avl | RFQ |
J2K-4730-207M | Howden Fluid Systems | relay electromagnet | Avl | RFQ |
J2K-4730-207M | Hi G Co Inc | relay electromagnet | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABTD | MOUNTING SLOT WIDTH | 0.118 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.122 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES DC INDUCTIVE LOAD |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
ABHP | OVERALL LENGTH | 1.320 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.062 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.078 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 0.410 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.500 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AKDX | WINDING QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 700.0 OHMS NOMINAL SINGLE WINDING |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 32.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 300.0 MILLIAMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
FEAT | SPECIAL FEATURES | FAILURE RATE 1.0 PERCENT PER 10,000 CYCLES |
TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote