Alternative NSN: 5945-01-166-9787 |
Item Name:Relay Electromagnet |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5945 Relays and Solenoids |
NIIN: 011669787 |
NCB Code: USA (01) |
Manufacturers: Navair And Navsea Managed , Omega Laboratories Inc , Jennings Technology Company Llc |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
2939222-1 | Navair And Navsea Managed | relay electromagnet | Avl | RFQ |
2939222-1 | Omega Laboratories Inc | relay electromagnet | Avl | RFQ |
2939222-1 | Jennings Technology Company Llc | relay electromagnet | Avl | RFQ |
D02566 | Omega Laboratories Inc | relay electromagnet | Avl | RFQ |
D02566 | Navair And Navsea Managed | relay electromagnet | Avl | RFQ |
D02566 | Jennings Technology Company Llc | relay electromagnet | Avl | RFQ |
DD2566 | Jennings Technology Company Llc | relay electromagnet | Avl | RFQ |
DD2566 | Navair And Navsea Managed | relay electromagnet | Avl | RFQ |
DD2566 | Omega Laboratories Inc | relay electromagnet | Avl | RFQ |
PR-55G | Omega Laboratories Inc | relay electromagnet | Avl | RFQ |
PR-55G | Navair And Navsea Managed | relay electromagnet | Avl | RFQ |
PR-55G | Jennings Technology Company Llc | relay electromagnet | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 6.100 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.110 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 5.140 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.610 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 4.640 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 13.435 INCHES MINIMUM AND 13.685 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 5.400 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | HUMIDITY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 390.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | INERT GAS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CRXH | TIME DELAY | 0.03 SECONDS MAXIMUM FIXED OPERATE TIME |
CRXH | TIME DELAY | 0.05 SECONDS MAXIMUM FIXED RELEASE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 100.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3000.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 45000.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 4 PIN ALL FUNCTIONS |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote