Alternative NSN: 5945-01-014-2439 |
Item Name:Relay Electromagnet |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5945 Relays and Solenoids |
NIIN: 010142439 |
NCB Code: USA (01) |
Manufacturers: Tyco Electronics Corp , Engineered Air Systems Inc , Tyco Electronics Agastat Relays , Drs Environmental Systems Inc , Hdt Expeditionary Systems Inc |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
4-1423159-9 | Tyco Electronics Corp | relay electromagnet | Avl | RFQ |
4-1423159-9 | Engineered Air Systems Inc | relay electromagnet | Avl | RFQ |
4-1423159-9 | Tyco Electronics Agastat Relays | relay electromagnet | Avl | RFQ |
7012ADI2 | Tyco Electronics Agastat Relays | relay electromagnet | Avl | RFQ |
7012ADI2 | Engineered Air Systems Inc | relay electromagnet | Avl | RFQ |
7012ADI2 | Tyco Electronics Corp | relay electromagnet | Avl | RFQ |
MSS91228-1 | Tyco Electronics Corp | relay electromagnet | Avl | RFQ |
MSS91228-1 | Tyco Electronics Agastat Relays | relay electromagnet | Avl | RFQ |
MSS91228-1 | Drs Environmental Systems Inc | relay electromagnet | Avl | RFQ |
MSS91228-1 | Hdt Expeditionary Systems Inc | relay electromagnet | Avl | RFQ |
MSS91228-1 | Engineered Air Systems Inc | relay electromagnet | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.090 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 4.520 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.250 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.199 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 2.50 SECONDS MINIMUM FIXED OPERATE TIME AND 50.00 SECONDS MAXIMUM FIXED OPERATE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 500.0 MILLIAMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 480.0 AC AND 110.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.