Alternative NSN: 5945-00-896-5181 |
Item Name:Relay Electromagnet |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5945 Relays and Solenoids |
NIIN: 008965181 |
NCB Code: USA (00) |
Manufacturers: Dri Relays Inc , Tyco Electronics Corp , Allied Controls Inc , Airpax Corp |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
189020 | Dri Relays Inc | relay electromagnet | Avl | RFQ |
189020 | Tyco Electronics Corp | relay electromagnet | Avl | RFQ |
189020 | Allied Controls Inc | relay electromagnet | Avl | RFQ |
520M85 | Allied Controls Inc | relay electromagnet | Avl | RFQ |
520M85 | Airpax Corp | relay electromagnet | Avl | RFQ |
520M85 | Tyco Electronics Corp | relay electromagnet | Avl | RFQ |
520M85 | Dri Relays Inc | relay electromagnet | Avl | RFQ |
855-95 | Tyco Electronics Corp | relay electromagnet | Avl | RFQ |
855-95 | Allied Controls Inc | relay electromagnet | Avl | RFQ |
855-95 | Dri Relays Inc | relay electromagnet | Avl | RFQ |
CE189020 | Dri Relays Inc | relay electromagnet | Avl | RFQ |
CE189020 | Allied Controls Inc | relay electromagnet | Avl | RFQ |
CE189020 | Tyco Electronics Corp | relay electromagnet | Avl | RFQ |
MHX6231 | Tyco Electronics Corp | relay electromagnet | Avl | RFQ |
MHX6231 | Dri Relays Inc | relay electromagnet | Avl | RFQ |
MHX6231 | Allied Controls Inc | relay electromagnet | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.250 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.562 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 1.310 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.870 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.152 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 190.0 OHMS MINIMUM SINGLE WINDING AND 240.0 OHMS MAXIMUM SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 6 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 0.025 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 15.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 35.0 MILLIAMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 8.8 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 20 PIN ALL FUNCTIONS |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote