Alternative NSN: 5945-00-808-4239 |
Item Name:Relay Electromagnet |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5945 Relays and Solenoids |
NIIN: 008084239 |
NCB Code: USA (00) |
Manufacturers: Northrop Grumman Systems Corporation , Dri Relays Inc , Genicom Corp , Communications Instruments Inc , Navair And Navsea Managed |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
136-005-0811 | Northrop Grumman Systems Corporation | relay electromagnet | Avl | RFQ |
136-005-0811 | Dri Relays Inc | relay electromagnet | Avl | RFQ |
136-005-0811 | Genicom Corp | relay electromagnet | Avl | RFQ |
3S2791G200AJ9 | Genicom Corp | relay electromagnet | Avl | RFQ |
3S2791G200AJ9 | Communications Instruments Inc | relay electromagnet | Avl | RFQ |
3S2791G200AJ9 | Dri Relays Inc | relay electromagnet | Avl | RFQ |
58A122D161-1 | Navair And Navsea Managed | relay electromagnet | Avl | RFQ |
58A122D161-1 | Dri Relays Inc | relay electromagnet | Avl | RFQ |
58A122D161-1 | Genicom Corp | relay electromagnet | Avl | RFQ |
58A5A83-11 | Dri Relays Inc | relay electromagnet | Avl | RFQ |
58A5A83-11 | Genicom Corp | relay electromagnet | Avl | RFQ |
P26F1P6A-3 | Genicom Corp | relay electromagnet | Avl | RFQ |
P26F1P6A-3 | Dri Relays Inc | relay electromagnet | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.125 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 1.060 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.096 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 30.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
ABHP | OVERALL LENGTH | 1.180 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 0.390 INCHES NOMINAL |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 552.0 OHMS NOMINAL SINGLE WINDING |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote