Alternative NSN: 5945-00-247-3645 |
Item Name:Relay Electromagnet |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5945 Relays and Solenoids |
NIIN: 002473645 |
NCB Code: USA (00) |
Manufacturers: Telemecanique Inc , Schneider Electric Usa Inc , Cosmodyne Llc , Care Laboratories Inc , Eaton Corp |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
2180FE11AA-66 | Telemecanique Inc | relay electromagnet | Avl | RFQ |
2180FE11AA-66 | Schneider Electric Usa Inc | relay electromagnet | Avl | RFQ |
2180FE11AA-66 | Cosmodyne Llc | relay electromagnet | Avl | RFQ |
2180FE11AA-66 | Care Laboratories Inc | relay electromagnet | Avl | RFQ |
3200751-1 | Schneider Electric Usa Inc | relay electromagnet | Avl | RFQ |
3200751-1 | Cosmodyne Llc | relay electromagnet | Avl | RFQ |
3200751-1 | Telemecanique Inc | relay electromagnet | Avl | RFQ |
LM3202674-PIECE-I | Telemecanique Inc | relay electromagnet | Avl | RFQ |
LM3202674-PIECE-I | Schneider Electric Usa Inc | relay electromagnet | Avl | RFQ |
LM3202674-PIECE-I | Cosmodyne Llc | relay electromagnet | Avl | RFQ |
MFE-11 | Eaton Corp | relay electromagnet | Avl | RFQ |
MFE-11 | Cosmodyne Llc | relay electromagnet | Avl | RFQ |
MFE-11 | Schneider Electric Usa Inc | relay electromagnet | Avl | RFQ |
MFE-11 | Telemecanique Inc | relay electromagnet | Avl | RFQ |
MFE11-51PA | Telemecanique Inc | relay electromagnet | Avl | RFQ |
MFE11-51PA | Schneider Electric Usa Inc | relay electromagnet | Avl | RFQ |
MFE11-51PA | Eaton Corp | relay electromagnet | Avl | RFQ |
MFE11-51PA | Cosmodyne Llc | relay electromagnet | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.680 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.380 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 2.310 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.680 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 0.160 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | FUNGUS PROOF AND HUMIDITY PROOF |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 267.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | DIAGONAL SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 250.0 AC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 SCREW ALL FUNCTIONS |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote