Alternative NSN: 5930-01-256-0194 |
Item Name:Switch Pressure |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5930 Switches |
NIIN: 012560194 |
NCB Code: USA (01) |
Manufacturers: Micro Pneumatic Logic Inc , Accurate Screwmachine Corporation , Raytheon Technical Services Company , Raytheon Company |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
5365914-3 | Micro Pneumatic Logic Inc | switch pressure | Avl | RFQ |
5365914-3 | Accurate Screwmachine Corporation | switch pressure | Avl | RFQ |
5365914-3 | Raytheon Technical Services Company | switch pressure | Avl | RFQ |
5365914-3 | Raytheon Company | switch pressure | Avl | RFQ |
MPL-503T-0-3 | Raytheon Technical Services Company | switch pressure | Avl | RFQ |
MPL-503T-0.3 | Micro Pneumatic Logic Inc | switch pressure | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
ABHP | OVERALL LENGTH | 1.870 INCHES NOMINAL |
ABKV | OUTSIDE DIAMETER | 0.200 INCHES NOMINAL ALL CONNECTIONS |
ABKW | OVERALL HEIGHT | 0.670 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.011 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.000 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.101 INCHES MINIMUM AND 0.107 INCHES MAXIMUM |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.771 INCHES MINIMUM AND 0.791 INCHES MAXIMUM |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.771 INCHES MINIMUM AND 0.791 INCHES MAXIMUM |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AWTN | OPERATING TEMP RATING | 65.0 DEG CELSIUS MAXIMUM |
AXGY | MOUNTING METHOD | BASE AND UNTHREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQYJ | MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
CSCF | TERMINAL TYPE | QUICK DISCONNECT,MALE |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 MILLIAMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 MILLIAMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE,PRESET |
CTYM | CONTACT ADJUSTMENT RANGE | 0.25/0.35 ACTUATION POINT INCHES OF WATER |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |
CTYX | CONTACT STIMULUS RATING | 0.25 ACTUATION POINT MINIMUM INCHES OF WATER AND 0.35 ACTUATION POINT MAXIMUM INCHES OF WATER |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SECOND VOLTAGE |
CTZL | PRESSURE CONNECTOR TYPE | BARBED,UNTHREADED EXTERNAL ALL CONNECTIONS |
FEAT | SPECIAL FEATURES | ADJUSTMENT SCREW HOLE FILLED TO PREVENT TAMPERING |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINAL SURFACES GOLD |
PRMT | PRECIOUS MATERIAL | GOLD |
STYL | STYLE DESIGNATOR | RECTANGULAR |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote