Alternative NSN: 5930-00-727-9709 |
Item Name:Switch Pressure |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5930 Switches |
NIIN: 007279709 |
NCB Code: USA (00) |
Manufacturers: Stafford Machinery Corp , Detroit Switch Inc |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
222-10NC1-2221108 | Stafford Machinery Corp | switch pressure | Avl | RFQ |
222-10NC1-2221108 | Detroit Switch Inc | switch pressure | Avl | RFQ |
22210 M C1-2221108 | Detroit Switch Inc | switch pressure | Avl | RFQ |
22210-M-C1-2221108 | Stafford Machinery Corp | switch pressure | Avl | RFQ |
F-15150-PIECE-227 | Stafford Machinery Corp | switch pressure | Avl | RFQ |
F-15150-PIECE-227 | Detroit Switch Inc | switch pressure | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 7.250 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 5.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 5.500 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.656 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AXGY | MOUNTING METHOD | BRACKET |
CMLP | THREAD QUANTITY PER INCH | 18 SINGLE PRESSURE CONNECTION |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,BOTH POSITIONS MAINTAINED |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 13.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 4.6 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | 1.00 TO 72.00 ACTUATION POINT OUNCE |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL THIRD VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
THSD | THREAD SERIES DESIGNATOR | NPT SINGLE PRESSURE CONNECTION |
CTHF | CONTACT LOAD CURRENT RATING | 2.7 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 1.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote