Alternative NSN: 5925-01-197-4165 |
Item Name:Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 011974165 |
NCB Code: USA (01) |
Manufacturers: Steris Corporation , Eaton Corp , American Sterilizer Company |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
JC1-B6-CB-A | Steris Corporation | circuit breaker | Avl | RFQ |
JC1-B6-CB-A | Eaton Corp | circuit breaker | Avl | RFQ |
JC1-B6-CB-A | American Sterilizer Company | circuit breaker | Avl | RFQ |
JC1S-B6-CB-A | American Sterilizer Company | circuit breaker | Avl | RFQ |
JC1S-B6-CB-A | Eaton Corp | circuit breaker | Avl | RFQ |
JC1S-B6-CB-A | Steris Corporation | circuit breaker | Avl | RFQ |
P-84386-001 | Steris Corporation | circuit breaker | Avl | RFQ |
P-84386-001 | Eaton Corp | circuit breaker | Avl | RFQ |
P-84386-001 | American Sterilizer Company | circuit breaker | Avl | RFQ |
P-93105-001 | American Sterilizer Company | circuit breaker | Avl | RFQ |
P-93105-001 | Eaton Corp | circuit breaker | Avl | RFQ |
P-93105-001 | Steris Corporation | circuit breaker | Avl | RFQ |
P093105-007 | Steris Corporation | circuit breaker | Avl | RFQ |
P093105-007 | Eaton Corp | circuit breaker | Avl | RFQ |
P093105-007 | American Sterilizer Company | circuit breaker | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ADAQ | BODY LENGTH | 2.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.750 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.750 INCHES NOMINAL AND 1.562 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.660 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | 6530-01-147-9531 |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
CBME | CUBIC MEASURE | 0.031 CUBIC FEET |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30.0 AMPERES AC AND 30.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC AND 65.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC AND 1000.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 SINGLE LOCATION |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 0.004 NOMINAL SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH BUTTON |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.109 INCHES |
CTJS | UNPACKAGED UNIT WEIGHT | 0.140 POUNDS NOMINAL |
CWJK | CASE MATERIAL | PLASTIC |
FEAT | SPECIAL FEATURES | ACTUATOR IS WHITE PLASTIC WITH ON-OFF IN BLACK 0.125 INCH LETTERING HOT STAMPED ON FACE,O/A DIM. 0.750 IN. WIDE,1.185 IN. LONG |
FREQ | FREQUENCY IN HERTZ | 400.0 SECOND LOCATION |
FREQ | FREQUENCY IN HERTZ | 50.0 FIRST LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 4 QUICK DISCONNECT,MALE |
ZZZP | PURCHASE DESCRIPTION IDENTIFICATION | 02964-P84386-001 |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote