Alternative NSN: 5925-00-821-6552 |
Item Name:Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 008216552 |
NCB Code: USA (00) |
Manufacturers: Eaton Corp |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
930-009-705 | Eaton Corp | circuit breaker | Avl | RFQ |
MP932 | Eaton Corp | circuit breaker | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ABXD | BUSHING LENGTH | 0.235 INCHES MINIMUM AND 0.265 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.203 INCHES MINIMUM AND 1.233 INCHES MAXIMUM |
ADTV | UNABLE TO DECODE | UNABLE TO DECODE |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.689 INCHES MINIMUM AND 0.179 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.218 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED BUSHING |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 7.5 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1200.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 PUSH-PULL |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE,TWO,AND THREE LINKED |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 15.000 MINIMUM AT 200 PCT AND 55.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CTJS | UNPACKAGED UNIT WEIGHT | 150.0 GRAMS NOMINAL |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB W/SCREW |
ADAQ | BODY LENGTH | 2.250 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 3 |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0.469 INCHES |
TEST | TEST DATA DOCUMENT | 76374-FT-12 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWIN |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote