Alternative NSN: 5925-00-813-2474 |
Item Name:Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 008132474 |
NCB Code: USA (00) |
Manufacturers: Graphic Controls Acquisition Corp , Eaton Corp , Spd Electrical Systems Inc , Westinghouse Electric Corp , Westwood Industries Inc , White Consolidated Industries Inc |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
458D509G13 4976D65G0 | Graphic Controls Acquisition Corp | circuit breaker | Avl | RFQ |
458D509G13 4976D65G06 | Eaton Corp | circuit breaker | Avl | RFQ |
458D509G13-4976D65G0 | Eaton Corp | circuit breaker | Avl | RFQ |
458D509G13-4976D65G0 | Spd Electrical Systems Inc | circuit breaker | Avl | RFQ |
458D509G13-4976D65G0 | Westinghouse Electric Corp | circuit breaker | Avl | RFQ |
458D509G13-4976D65G06 | Westinghouse Electric Corp | circuit breaker | Avl | RFQ |
458D509G13-4976D65G06 | Spd Electrical Systems Inc | circuit breaker | Avl | RFQ |
5682D24G15 | Eaton Corp | circuit breaker | Avl | RFQ |
707009 ITEM 410 | Westwood Industries Inc | circuit breaker | Avl | RFQ |
83E2227 | Eaton Corp | circuit breaker | Avl | RFQ |
ET74403 | Spd Electrical Systems Inc | circuit breaker | Avl | RFQ |
ET85137ETN2730 | Westinghouse Electric Corp | circuit breaker | Avl | RFQ |
ET85137ETN2730 | Spd Electrical Systems Inc | circuit breaker | Avl | RFQ |
ET85137ETN2730 | Eaton Corp | circuit breaker | Avl | RFQ |
ET85137XETN2730 | Westinghouse Electric Corp | circuit breaker | Avl | RFQ |
ET85137XETN2730 | Eaton Corp | circuit breaker | Avl | RFQ |
ET85137XETN2730 | Spd Electrical Systems Inc | circuit breaker | Avl | RFQ |
ETN2742-00S01 | Spd Electrical Systems Inc | circuit breaker | Avl | RFQ |
ETN2752-00S01 | Eaton Corp | circuit breaker | Avl | RFQ |
ETN2752-00S01 | Spd Electrical Systems Inc | circuit breaker | Avl | RFQ |
ETN2752-00S01 | Westinghouse Electric Corp | circuit breaker | Avl | RFQ |
S5682D24G15 | White Consolidated Industries Inc | circuit breaker | Avl | RFQ |
S5682D24G15 | Westinghouse Electric Corp | circuit breaker | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 6.500 INCHES NOMINAL |
ADAT | BODY WIDTH | 4.125 INCHES NOMINAL |
ADAU | BODY HEIGHT | 4.125 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 5.562 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.375 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.190 INCHES NOMINAL |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE,DOUBLE THROW |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.375 INCHES NOMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.188 INCHES NOMINAL |
AKPX | POLE QUANTITY | 3 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBBL | FEATURES PROVIDED | ADJUSTABLE TRIP RELEASE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 600.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 15000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 140.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 2 ALARM |
CPSF | ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS | 600.0 TO 700.0 AC ALL LOCATIONS |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE AND INTERNAL AT POLE THREE |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 50.0 AC AND 50.0 DC |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 120.0 AC AND 120.0 DC |
CWJK | CASE MATERIAL | PLASTIC |
FEAT | SPECIAL FEATURES | SHUNT TRIP |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 QUICK DISCONNECT,FEMALE |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.312 INCHES NOMINAL |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC ALL LOCATIONS |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CRTK | SWITCH TERMINAL TYPE | WIRE LEAD |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote