Alternative NSN: 5920-00-577-8735 |
Item Name:Fuse Cartridge |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5920 Fuses Arresters Absorbers and Protector |
NIIN: 005778735 |
NCB Code: USA (00) |
Manufacturers: Military Standards Promulgated By Military Departments Under Authority Of Defens , Military Specifications Promulgated By Military Departments/Agencies Under Autho , Hollingsworth John R Co , Cooper Bussmann Corp , Federal Pacific Electric Co , Munters Corp , Parameter Generation And Control , Allis Chalmers Corp |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
MS90088-27 | Military Standards Promulgated By Military Departments Under Authority Of Defens | fuse cartridge | Avl | RFQ |
MILF15160-15 | Military Specifications Promulgated By Military Departments/Agencies Under Autho | fuse cartridge | Avl | RFQ |
MIL-PRF-15160/15 | Military Specifications Promulgated By Military Departments/Agencies Under Autho | fuse cartridge | Avl | RFQ |
JHP133-763 | Hollingsworth John R Co | fuse cartridge | Avl | RFQ |
JHP124-026 | Hollingsworth John R Co | fuse cartridge | Avl | RFQ |
JHP108-581 | Hollingsworth John R Co | fuse cartridge | Avl | RFQ |
FRN10 | Cooper Bussmann Corp | fuse cartridge | Avl | RFQ |
F15B250V10A | Military Specifications Promulgated By Military Departments/Agencies Under Autho | fuse cartridge | Avl | RFQ |
ENC10 | Federal Pacific Electric Co | fuse cartridge | Avl | RFQ |
ECN10 | Federal Pacific Electric Co | fuse cartridge | Avl | RFQ |
A90193-05 | Munters Corp | fuse cartridge | Avl | RFQ |
409-108 | Parameter Generation And Control | fuse cartridge | Avl | RFQ |
14-131-943-00-023 | Allis Chalmers Corp | fuse cartridge | Avl | RFQ |
1110 | Federal Pacific Electric Co | fuse cartridge | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | TUBE TYPE |
ABHP | OVERALL LENGTH | 1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 0.556 INCHES MINIMUM AND 0.568 INCHES MAXIMUM |
AEBJ | CONTINUOUS CURRENT RATING IN AMPS | 10.000 |
AFXE | MAXIMUM VOLTAGE RATING IN VOLTS | 250.0 AC AND 250.0 DC |
AFXF | CIRCUIT OVER-CURRENT INTERRUPTION TYPE | TIME DELAY |
AFXH | INTERRUPTION INDICATOR METHOD | OPAQUE BODY |
CBBL | FEATURES PROVIDED | NONRENEWABLE FUSIBLE ELEMENT |
CQPB | CIRCUIT OVER-CURRENT INTERRUPTION DELAY TIME IN SECONDS | 10.0 400 PCT OF CURRENT RATING |
CWJK | CASE MATERIAL | FIBER |
SFTT | SURFACE TREATMENT | NICKEL TERMINAL |
TEST | TEST DATA DOCUMENT | 81349-MIL-F-15160 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-F-15160/15 GOVERNMENT SPECIFICATION |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote