Alternative NSN: 5915-00-615-4079 |
Item Name:Filter Band Pass |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5915 Filters and Networks |
NIIN: 006154079 |
NCB Code: USA (00) |
Manufacturers: Navair And Navsea Managed , Raytheon Company , Robertson Instrument Co , Raytheon Technical Services Company , Bulova Technologies L L C |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
2182138-10 | Navair And Navsea Managed | filter band pass | Avl | RFQ |
2182138-10 | Raytheon Company | filter band pass | Avl | RFQ |
2182138-10 | Robertson Instrument Co | filter band pass | Avl | RFQ |
3251-1042P10 | Raytheon Company | filter band pass | Avl | RFQ |
3251-1042P10 | Robertson Instrument Co | filter band pass | Avl | RFQ |
3251-1042P10 | Raytheon Technical Services Company | filter band pass | Avl | RFQ |
3251-1042P10 | Navair And Navsea Managed | filter band pass | Avl | RFQ |
619P10 | Robertson Instrument Co | filter band pass | Avl | RFQ |
619P10 | Raytheon Company | filter band pass | Avl | RFQ |
619P10 | Navair And Navsea Managed | filter band pass | Avl | RFQ |
69AP10 | Navair And Navsea Managed | filter band pass | Avl | RFQ |
69AP10 | Raytheon Company | filter band pass | Avl | RFQ |
69AP10 | Bulova Technologies L L C | filter band pass | Avl | RFQ |
69AP10 | Robertson Instrument Co | filter band pass | Avl | RFQ |
8180026-1P10 | Robertson Instrument Co | filter band pass | Avl | RFQ |
8180026-1P10 | Raytheon Company | filter band pass | Avl | RFQ |
8180026-1P10 | Navair And Navsea Managed | filter band pass | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 1.750 INCHES NOMINAL |
ADAQ | BODY LENGTH | 2.500 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.000 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.375 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.062 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.188 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | 25.0 TO 90.0 DEG CELSIUS |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 142.901 KILOHERTZ BLANK |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 10.0 KILOHMS BLANK |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 43.0 KILOHMS BLANK |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED STUD 1ST FUNCTION |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 0.9 BLANK |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET OUTPUT 2ND FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB,SOLDER LUG GROUND 3RD FUNCTION |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 142.766 KILOHERTZ BLANK AND 143.036 KILOHERTZ BLANK |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote