Alternative NSN: 5910-01-021-1026 |
Item Name:Capacitor Fixed Cer |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5910 Capacitors |
NIIN: 010211026 |
NCB Code: USA (01) |
Manufacturers: Aerovox Corp , Alpine Tool And Mfg Co , Illinois Tool Works Inc , Standard Industries , Raytheon Company |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
1123-15 | Aerovox Corp | capacitor fixed cer | Avl | RFQ |
1123-15 | Alpine Tool And Mfg Co | capacitor fixed cer | Avl | RFQ |
1123-15 | Illinois Tool Works Inc | capacitor fixed cer | Avl | RFQ |
4917-15 | Illinois Tool Works Inc | capacitor fixed cer | Avl | RFQ |
4917-15 | Alpine Tool And Mfg Co | capacitor fixed cer | Avl | RFQ |
4917-15 | Aerovox Corp | capacitor fixed cer | Avl | RFQ |
905543-15 | Aerovox Corp | capacitor fixed cer | Avl | RFQ |
905543-15 | Alpine Tool And Mfg Co | capacitor fixed cer | Avl | RFQ |
905543-15 | Standard Industries | capacitor fixed cer | Avl | RFQ |
905543-15 | Raytheon Company | capacitor fixed cer | Avl | RFQ |
905543-15 | Illinois Tool Works Inc | capacitor fixed cer | Avl | RFQ |
H543-15 | Illinois Tool Works Inc | capacitor fixed cer | Avl | RFQ |
H543-15 | Alpine Tool And Mfg Co | capacitor fixed cer | Avl | RFQ |
H543-15 | Aerovox Corp | capacitor fixed cer | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACEW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACEW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
AARF | MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | N-3 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABHP | UNABLE TO DECODE | UNABLE TO DECODE |
ABJT | TERMINAL LENGTH | 1.250 INCHES MINIMUM1.250 INCHES MINIMUM |
ABKW | UNABLE TO DECODE | UNABLE TO DECODE |
ADAQ | BODY LENGTH | 0.300 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.300 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.100 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.200 INCHES NOMINAL |
AEBT | TERMINAL DIAMETER | 0.024 INCHES MINIMUM AND 0.029 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
CQBF | INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 10000.0 MEGOHMS |
CQBQ | CAPACITANCE VALUE PER SECTION | 1000.000 PICOFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
CQLZ | TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | 0.0 SINGLE SECTION |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 50.0 DC SINGLE SECTION |
CRHD | TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | -30.0/30.0 SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -2.00 TO 2.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | PLASTIC |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.1500 |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote