Alternative NSN: 5905-01-069-2536 |
Item Name:Resistor Network Fi |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 010692536 |
NCB Code: USA (01) |
Manufacturers: Schlumberger Industries Inc , Enerdis , Data I O Corporation , Bi Technologies Corporation , Vishay Sa |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
087810315 | Schlumberger Industries Inc | resistor network fi | Avl | RFQ |
087810315 | Enerdis | resistor network fi | Avl | RFQ |
087810315 | Data I O Corporation | resistor network fi | Avl | RFQ |
087810315 | Bi Technologies Corporation | resistor network fi | Avl | RFQ |
119-0001 | Bi Technologies Corporation | resistor network fi | Avl | RFQ |
119-0001 | Data I O Corporation | resistor network fi | Avl | RFQ |
119-0001 | Enerdis | resistor network fi | Avl | RFQ |
784-1-R2-2K | Data I O Corporation | resistor network fi | Avl | RFQ |
784-1-R2-2K | Enerdis | resistor network fi | Avl | RFQ |
784-1-R2.2K | Bi Technologies Corporation | resistor network fi | Avl | RFQ |
SIL8-7-2K2G | Vishay Sa | resistor network fi | Avl | RFQ |
SIL8-7-2K2G | Enerdis | resistor network fi | Avl | RFQ |
SIL8-7-2K2G | Data I O Corporation | resistor network fi | Avl | RFQ |
SIL8-7-2K2G | Bi Technologies Corporation | resistor network fi | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ADAT | BODY WIDTH | 0.090 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.350 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | LADDER NETWORK |
AEFB | POWER DISSIPATION RATING IN WATTS | 2.000 TOTAL NETWORK |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 7 EACH RESISTOR |
STYL | STYLE DESIGNATOR | SINGLE INLINE |
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -175.0/175.0 |
AAPP | III ELECTRICAL RESISTANCE | 2.200 KILOHMS EACH RESISTOR |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -2.000/2.000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 125.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 125.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARA | TERMINAL QUANTITY | 8 |
AARB | TERMINAL TYPE | PIN |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.125 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.780 INCHES MAXIMUM |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote