Alternative NSN: 5905-00-952-4951 |
Item Name:Resistor Fixed Wire |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 009524951 |
NCB Code: USA (00) |
Manufacturers: Ward Leonard Electric Company Inc , Acme Electric Corporation , National Aerospace Standards , Military Specifications Promulgated By Military Departments/Agencies Under Autho |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
AM62385 | Ward Leonard Electric Company Inc | resistor fixed wire | Avl | RFQ |
AM62385 | Acme Electric Corporation | resistor fixed wire | Avl | RFQ |
F62362PC6 | Ward Leonard Electric Company Inc | resistor fixed wire | Avl | RFQ |
F62362PC6 | Acme Electric Corporation | resistor fixed wire | Avl | RFQ |
K46396-48-8 | Ward Leonard Electric Company Inc | resistor fixed wire | Avl | RFQ |
K46396-48-8 | Acme Electric Corporation | resistor fixed wire | Avl | RFQ |
MILR15109 | National Aerospace Standards | resistor fixed wire | Avl | RFQ |
MILR15109 | Military Specifications Promulgated By Military Departments/Agencies Under Autho | resistor fixed wire | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPP | ELECTRICAL RESISTANCE | 48.800 OHMS48.800 OHMS48.800 OHMS48.800 OHMS48.800 OHMS48.800 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -10.000 TO 10.000-10.000 TO 10.000-10.000 TO 10.000-10.000 TO 10.000-10.000 TO 10.000-10.000 TO 10.000 |
AAPR | FIXED TAP QUANTITY | 333333 |
AAQF | UNABLE TO DECODE | UNABLE TO DECODE |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 425.0425.0425.0425.0425.0 |
AAQZ | UNABLE TO DECODE | UNABLE TO DECODE |
AARB | UNABLE TO DECODE | UNABLE TO DECODE |
AARE | REACTANCE CHARACTERISTIC | INDUCTIVEINDUCTIVEINDUCTIVE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.688 INCHES NOMINAL0.688 INCHES NOMINAL0.688 INCHES NOMINAL |
ABPM | BODY DIAMETER | 1.875 INCHES NOMINAL1.875 INCHES NOMINAL1.875 INCHES NOMINAL |
ADAQ | BODY LENGTH | 11.750 INCHES NOMINAL11.750 INCHES NOMINAL11.750 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 550.000 FREE AIR550.000 FREE AIR550.000 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 50.0 DEG CELSIUS50.0 DEG CELSIUS50.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | UNINCLOSEDUNINCLOSEDUNINCLOSED |
CQFD | SECTION NOMINAL RESISTANCE | 12.200 OHMS 1ST SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 12.200 OHMS 2ND SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 12.200 OHMS 3RD SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 12.200 OHMS 4TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | UNABLE TO DECODE |
CQFK | FIXED TAP TERMINAL TYPE | TAB W/SCREWTAB W/SCREW |
CSCF | TERMINAL TYPE | TAB W/SCREWTAB W/SCREW |
STYL | STYLE DESIGNATOR | RADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH END |
ZZZT | NONDEFINITIVE SPEC/STD DATA | EW FORMEW FORMEW FORMEW FORMEW FORM |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote