Alternative NSN: 5905-00-755-5060 |
Item Name:Resistor Fixed Comp |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 007555060 |
NCB Code: USA (00) |
Manufacturers: Direction Centrale Du Materiel De , General Electric Company , Rockwell Automation Ltd , Lucent Technologies Inc , Lockheed Martin Corporation , Solartron Electronics Inc |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
7630845P333 | Direction Centrale Du Materiel De | resistor fixed comp | Avl | RFQ |
7630845P333 | General Electric Company | resistor fixed comp | Avl | RFQ |
7630845P333 | Rockwell Automation Ltd | resistor fixed comp | Avl | RFQ |
813190-85 | Rockwell Automation Ltd | resistor fixed comp | Avl | RFQ |
813190-85 | Lucent Technologies Inc | resistor fixed comp | Avl | RFQ |
813190-85 | Lockheed Martin Corporation | resistor fixed comp | Avl | RFQ |
813190-85 | General Electric Company | resistor fixed comp | Avl | RFQ |
813190-85 | Direction Centrale Du Materiel De | resistor fixed comp | Avl | RFQ |
HB3335 | Direction Centrale Du Materiel De | resistor fixed comp | Avl | RFQ |
HB3335 | Rockwell Automation Ltd | resistor fixed comp | Avl | RFQ |
HB3335 | General Electric Company | resistor fixed comp | Avl | RFQ |
ND60293-001 | Solartron Electronics Inc | resistor fixed comp | Avl | RFQ |
ND60293-001 | Rockwell Automation Ltd | resistor fixed comp | Avl | RFQ |
ND60293-001 | General Electric Company | resistor fixed comp | Avl | RFQ |
ND60293-001 | Direction Centrale Du Materiel De | resistor fixed comp | Avl | RFQ |
RES 033K00 005 0002W AG08X018 | Direction Centrale Du Materiel De | resistor fixed comp | Avl | RFQ |
RES-033K00-005-0002W-AG08X018 | Rockwell Automation Ltd | resistor fixed comp | Avl | RFQ |
RES-033K00-005-0002W-AG08X018 | General Electric Company | resistor fixed comp | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPP | ELECTRICAL RESISTANCE | 33.000 KILOHMS |
AAQZ | UNABLE TO DECODE | UNABLE TO DECODE |
ADAQ | BODY LENGTH | 0.688 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000 TO 5.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150.0 |
AARB | UNABLE TO DECODE | UNABLE TO DECODE |
ABJT | TERMINAL LENGTH | 1.500 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.312 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 2.000 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 70.0 DEG CELSIUS |
CSCF | TERMINAL TYPE | WIRE LEAD |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote