Alternative NSN: 5905-00-161-0632 |
Item Name:Resistor Fixed Wire |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 001610632 |
NCB Code: USA (00) |
Manufacturers: Kaman Aerospace Corporation , Richmond Ring Co , Shallcross Inc , White Consolidated Industries Inc , Shallco Inc |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
7007 | Kaman Aerospace Corporation | resistor fixed wire | Avl | RFQ |
7007 | Richmond Ring Co | resistor fixed wire | Avl | RFQ |
7007 | Shallcross Inc | resistor fixed wire | Avl | RFQ |
7007 | White Consolidated Industries Inc | resistor fixed wire | Avl | RFQ |
7007-4002F | White Consolidated Industries Inc | resistor fixed wire | Avl | RFQ |
7007-4002F | Shallcross Inc | resistor fixed wire | Avl | RFQ |
7007-4002F | Richmond Ring Co | resistor fixed wire | Avl | RFQ |
7007-4002F | Kaman Aerospace Corporation | resistor fixed wire | Avl | RFQ |
900318-001 | Kaman Aerospace Corporation | resistor fixed wire | Avl | RFQ |
900318-001 | Richmond Ring Co | resistor fixed wire | Avl | RFQ |
900318-001 | White Consolidated Industries Inc | resistor fixed wire | Avl | RFQ |
R2185-1 | White Consolidated Industries Inc | resistor fixed wire | Avl | RFQ |
R2185-1 | Shallcross Inc | resistor fixed wire | Avl | RFQ |
R2185-1 | Shallco Inc | resistor fixed wire | Avl | RFQ |
R2185-1 | Richmond Ring Co | resistor fixed wire | Avl | RFQ |
R2185-1 | Kaman Aerospace Corporation | resistor fixed wire | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -8.0 TO 8.0 |
AAPP | ELECTRICAL RESISTANCE | 40.000 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 145.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 145.0 |
AAQZ | UNABLE TO DECODE | UNABLE TO DECODE |
AARB | UNABLE TO DECODE | UNABLE TO DECODE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.484 INCHES MINIMUM AND 1.515 INCHES MAXIMUM |
ABPM | BODY DIAMETER | 0.188 INCHES MINIMUM AND 0.218 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.376 INCHES MINIMUM AND 0.406 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.125 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 125.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CBME | CUBIC MEASURE | 0.015 CUBIC INCHES |
CSCF | TERMINAL TYPE | WIRE LEAD |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote