Alternative NSN: 5905-00-126-0529 |
Item Name:Resistor Fixed Comp |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 001260529 |
NCB Code: USA (00) |
Manufacturers: United Technologies Corp , Trw Inc , Veeco Instruments Ltd , Hamilton Sundstrand Corporation , Rockwell Automation Ltd |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
80116-622 | United Technologies Corp | resistor fixed comp | Avl | RFQ |
80116-622 | Trw Inc | resistor fixed comp | Avl | RFQ |
80116-622 | Veeco Instruments Ltd | resistor fixed comp | Avl | RFQ |
80116-622 | Hamilton Sundstrand Corporation | resistor fixed comp | Avl | RFQ |
DEB-6225 | Trw Inc | resistor fixed comp | Avl | RFQ |
DEB-6225 | Hamilton Sundstrand Corporation | resistor fixed comp | Avl | RFQ |
DEB-6225 | Veeco Instruments Ltd | resistor fixed comp | Avl | RFQ |
DEB-8225 | Trw Inc | resistor fixed comp | Avl | RFQ |
DEB-8225 | Veeco Instruments Ltd | resistor fixed comp | Avl | RFQ |
DEB-8225 | Hamilton Sundstrand Corporation | resistor fixed comp | Avl | RFQ |
EB6225 | Rockwell Automation Ltd | resistor fixed comp | Avl | RFQ |
GBT1-2-622J | Hamilton Sundstrand Corporation | resistor fixed comp | Avl | RFQ |
GBT1-2-622J | Trw Inc | resistor fixed comp | Avl | RFQ |
GBT1-2-622J | Veeco Instruments Ltd | resistor fixed comp | Avl | RFQ |
SCD80116-622 | Veeco Instruments Ltd | resistor fixed comp | Avl | RFQ |
SCD80116-622 | United Technologies Corp | resistor fixed comp | Avl | RFQ |
SCD80116-622 | Trw Inc | resistor fixed comp | Avl | RFQ |
SCD80116-622 | Hamilton Sundstrand Corporation | resistor fixed comp | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPP | ELECTRICAL RESISTANCE | 6.200 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000 TO 5.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150.0 |
AAQZ | UNABLE TO DECODE | UNABLE TO DECODE |
AARB | UNABLE TO DECODE | UNABLE TO DECODE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABPM | BODY DIAMETER | 0.140 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.375 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.500 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 70.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CSCF | TERMINAL TYPE | WIRE LEAD |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 07148-SCD80116 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
5905-00-000-0136 (5905000000136) |
5905-00-001-2573 (5905000012573) |
5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) |
5905-00-001-2814 (5905000012814) |
5905-00-001-2815 (5905000012815) |
5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) |
5905-00-001-2821 (5905000012821) |
5905-00-001-2822 (5905000012822) |
5905-00-001-2826 (5905000012826) |
5905-00-001-2827 (5905000012827) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote