Alternative NSN: 4140-01-026-1378 |
Item Name:Fan Tubeaxial |
FSG: 41 Refrigeration Air Conditioning and Air Circulating Equipment |
Federal Supply Class (FSC): 4140 Fans Air Circulators and Blower Equipment |
NIIN: 010261378 |
NCB Code: USA (01) |
Manufacturers: Rosenberg Usa Inc , Rca Corp , Delta Data Systems Corp |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
206F012U01 | Rosenberg Usa Inc | fan tubeaxial | Avl | RFQ |
206F012U01 | Rca Corp | fan tubeaxial | Avl | RFQ |
206F012U01 | Delta Data Systems Corp | fan tubeaxial | Avl | RFQ |
3024402PT1 | Rca Corp | fan tubeaxial | Avl | RFQ |
3024402PT1 | Delta Data Systems Corp | fan tubeaxial | Avl | RFQ |
3024402PT1 | Rosenberg Usa Inc | fan tubeaxial | Avl | RFQ |
3610-PS-12T-B10 | Rosenberg Usa Inc | fan tubeaxial | Avl | RFQ |
3610-PS-12T-B10 | Delta Data Systems Corp | fan tubeaxial | Avl | RFQ |
3610-PS-12T-B10 | Rca Corp | fan tubeaxial | Avl | RFQ |
99XM-2182 | Rca Corp | fan tubeaxial | Avl | RFQ |
99XM-2182 | Delta Data Systems Corp | fan tubeaxial | Avl | RFQ |
99XM-2182 | Rosenberg Usa Inc | fan tubeaxial | Avl | RFQ |
99XM-2182-000 | Rosenberg Usa Inc | fan tubeaxial | Avl | RFQ |
99XM-2182-000 | Rca Corp | fan tubeaxial | Avl | RFQ |
99XM-2182-000 | Delta Data Systems Corp | fan tubeaxial | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
CWLX | Housing Inside Diameter | 3.543 INCHES NOMINAL |
MATT | Material | PLASTIC POLYCARBONATE AND GLASS FIBER BLADE |
CWLY | Prime Mover Drive Shaft Bearing Type | BALL |
AGBD | Electrical Connection Type | CONNECTOR PLUG |
FAAZ | Phase | SINGLE |
SFTT | Surface Treatment | PAINT HOUSING |
FREQ | Frequency In Hertz | 50.0 AND 60.0 |
ADZC | Environmental Protection | VIBRATION PROOF |
AKCV | Drive Type | DIRECT |
AXHR | Mounting Facility Type And Quantity | 2 FLANGE AND 6 UNTHREADED HOLE |
AEHY | Ambient Temp At Full Rated Power | -10.0 DEG CELSIUS AND 70.0 DEG CELSIUS |
ADNK | Flow Direction | INWARD |
AJLY | Static Pressure At Specified Air Flow Rate | 0.0 INCHES OF WATER |
CSYL | Prime Mover Power Rating | 0.008 HORSEPOWER |
CSBH | Voltage In Volts And Current Type | 115.0 AC |
ABBB | Speed Adjustments | SINGLE SPEED |
CQKX | Air Flow Rate | 17.000 CUBIC FEET PER MINUTE NOMINAL |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
ABRY | Length | 0.984 INCHES NOMINAL |
FEAT | Special Features | 3.622 IN. SQ MTG FLANGE W/CORNER HOLES PROVIDED AT BOTH ENDS OF VENTURI TUBE,RATED 1450 RPM AT 50 HZ OPERATION,CLASS A INSULATION MOTOR WINDINGS |
MATT | Material | ZINC ALLOY HOUSING |
STYL | Style Designator | FIXED |
AYSY | Rotation Direction For Which Designed | CLOCKWISE |
AEQC | Operating Speed At Rated Capacity In Rpm | 1500 |
AKNA | Inclosure Type | FULLY INCLOSED |
4110-00-135-8803 (4110001358803) |
4110-00-141-1372 (4110001411372) |
4110-00-141-1481 (4110001411481) |
4110-00-142-1466 (4110001421466) |
4110-00-142-5132 (4110001425132) |
4110-00-143-9156 (4110001439156) |
4110-00-143-9241 (4110001439241) |
4110-00-148-5868 (4110001485868) |
4110-00-148-5869 (4110001485869) |
4110-00-148-5870 (4110001485870) |
4110-00-170-8230 (4110001708230) |
4110-00-170-8233 (4110001708233) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote