Alternative NSN: 4140-00-620-5765 |
Item Name:Fan Centrifugal |
FSG: 41 Refrigeration Air Conditioning and Air Circulating Equipment |
Federal Supply Class (FSC): 4140 Fans Air Circulators and Blower Equipment |
NIIN: 006205765 |
NCB Code: USA (00) |
Manufacturers: Eastern Air Devices Inc , Curtiss Wright Controls Inc , Rockwell Collins Inc |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
009-1361-00 | Eastern Air Devices Inc | fan centrifugal | Avl | RFQ |
009-1361-00 | Curtiss Wright Controls Inc | fan centrifugal | Avl | RFQ |
009-1361-00 | Rockwell Collins Inc | fan centrifugal | Avl | RFQ |
009-1361-000 | Rockwell Collins Inc | fan centrifugal | Avl | RFQ |
009-1361-000 | Eastern Air Devices Inc | fan centrifugal | Avl | RFQ |
009-1361-000 | Curtiss Wright Controls Inc | fan centrifugal | Avl | RFQ |
B20X3R-6 | Curtiss Wright Controls Inc | fan centrifugal | Avl | RFQ |
B20X3R-6 | Eastern Air Devices Inc | fan centrifugal | Avl | RFQ |
B20X3R-6 | Rockwell Collins Inc | fan centrifugal | Avl | RFQ |
FBC1615B-19 | Rockwell Collins Inc | fan centrifugal | Avl | RFQ |
FBC1615B-19 | Eastern Air Devices Inc | fan centrifugal | Avl | RFQ |
FBC1615B-19 | Curtiss Wright Controls Inc | fan centrifugal | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
CXCB | DISCHARGE DIRECTION | HORIZONTAL |
FREQ | FREQUENCY IN HERTZ | 400.0 |
SFTT | SURFACE TREATMENT | ANODIZE OVERALL |
AEHY | AMBIENT TEMP AT FULL RATED POWER | -55.0 DEG CELSIUS AND 85.0 DEG CELSIUS |
AEQC | OPERATING SPEED AT RATED CAPACITY IN RPM | 8000.0 |
HGTH | HEIGHT | 3.250 INCHES NOMINAL |
AJLU | OUTLET INSIDE WIDTH | 1.030 INCHES NOMINAL |
FAAZ | PHASE | SINGLE |
MATT | MATERIAL | ALUMINUM OVERALL |
ABGL | WIDTH | 4.406 INCHES NOMINAL |
AGBD | ELECTRICAL CONNECTION TYPE | CORD W/ATTACHED PLUG |
STYL | STYLE DESIGNATOR | FIXED, RECTANGULAR OUTLETS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED HOLE |
CRWJ | OUTLET LOCATION | BOTTOM |
AKCV | DRIVE TYPE | DIRECT |
AJLV | OUTLET INSIDE HEIGHT | 1.343 INCHES NOMINAL |
CWLY | PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
AYSY | ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
CQKX | AIR FLOW RATE | 34.000 CUBIC FEET PER MINUTE NOMINAL |
AJLY | STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 1.8 INCHES OF WATER |
ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
ADZC | ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT AND HUMIDITY PROOF AND VIBRATION PROOF |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ABRY | LENGTH | 3.500 INCHES NOMINAL |
CSYL | PRIME MOVER POWER RATING | 0.025 HORSEPOWER |
4110-00-135-8803 (4110001358803) |
4110-00-141-1372 (4110001411372) |
4110-00-141-1481 (4110001411481) |
4110-00-142-1466 (4110001421466) |
4110-00-142-5132 (4110001425132) |
4110-00-143-9156 (4110001439156) |
4110-00-143-9241 (4110001439241) |
4110-00-148-5868 (4110001485868) |
4110-00-148-5869 (4110001485869) |
4110-00-148-5870 (4110001485870) |
4110-00-170-8230 (4110001708230) |
4110-00-170-8233 (4110001708233) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote