Alternative NSN: 4130-00-089-9065 |
Item Name:Compressor Unit Ref |
FSG: 41 Refrigeration Air Conditioning and Air Circulating Equipment |
Federal Supply Class (FSC): 4130 Refrigeration and Air Condition Components |
NIIN: 000899065 |
NCB Code: USA (00) |
Manufacturers: Copeland Corporation Ltd , Curtis Toledo Inc , Fischer And Porter Co |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
10A1156-55EM1010 | Copeland Corporation Ltd | compressor unit ref | Avl | RFQ |
10A1156-55EM1010 | Curtis Toledo Inc | compressor unit ref | Avl | RFQ |
10A1156-55EM1010 | Fischer And Porter Co | compressor unit ref | Avl | RFQ |
10A1156-55M1010 | Fischer And Porter Co | compressor unit ref | Avl | RFQ |
10A1156-55M1010 | Curtis Toledo Inc | compressor unit ref | Avl | RFQ |
10A1156-55M1010 | Copeland Corporation Ltd | compressor unit ref | Avl | RFQ |
FRSC2075A | Fischer And Porter Co | compressor unit ref | Avl | RFQ |
FRSC2075A | Curtis Toledo Inc | compressor unit ref | Avl | RFQ |
FRSC2075A | Copeland Corporation Ltd | compressor unit ref | Avl | RFQ |
MRG750 | Copeland Corporation Ltd | compressor unit ref | Avl | RFQ |
MRG750 | Curtis Toledo Inc | compressor unit ref | Avl | RFQ |
MRG750 | Fischer And Porter Co | compressor unit ref | Avl | RFQ |
MRH40760TFD200 | Fischer And Porter Co | compressor unit ref | Avl | RFQ |
MRH40760TFD200 | Curtis Toledo Inc | compressor unit ref | Avl | RFQ |
MRH40760TFD200 | Copeland Corporation Ltd | compressor unit ref | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAXP | Cooling System Design | SINGLE |
AAXV | Unloader Type | AUTOMATIC |
CXNT | Brake Power Required | 7.500 HORSEPOWER |
AAXY | Reciprocating Compressor Design | SINGLE ACTING |
AAYD | Stage Quantity | 1 |
AAYU | Intake Connection Type | FLARED TUBE |
MRC | Decoded Requirement | Clear Text Reply |
AAXK | Gas For Which Designed | REFRIGERANT R-22 |
FAAZ | Phase | THREE |
FREQ | Frequency In Hertz | 60 |
AAXJ | Duty Cycle In Percent | 100 |
AAXX | Mounting Type | BASE |
AAYT | Intake Connection Quantity | 1 |
CSBH | Voltage In Volts And Current Type | 440.0 AC |
CQJY | Current Type And Rating In Amps | 15.0 AC |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
AAXR | Compressor Cooling Medium | REFRIGERANT |
AAXS | Prime Mover Cooling Medium | AIR |
AAXZ | Cylinder Quantity | 2 |
AAYA | Cylinder Arrangement Style | VERTICAL DESIGN |
AAYV | Discharge Connection Quantity | 1 |
AAXL | Discharge Flow Rate | 18.930 CUBIC FEET PER MINUTE |
AAYW | Discharge Connection Type | FLARED TUBE |
AAXM | Discharge Pressure | 246.000 POUNDS PER SQUARE INCH GAGE |
4110-00-135-8803 (4110001358803) |
4110-00-141-1372 (4110001411372) |
4110-00-141-1481 (4110001411481) |
4110-00-142-1466 (4110001421466) |
4110-00-142-5132 (4110001425132) |
4110-00-143-9156 (4110001439156) |
4110-00-143-9241 (4110001439241) |
4110-00-148-5868 (4110001485868) |
4110-00-148-5869 (4110001485869) |
4110-00-148-5870 (4110001485870) |
4110-00-170-8230 (4110001708230) |
4110-00-170-8233 (4110001708233) |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Will Remember Us the Next Time You are Looking for Parts.
Request for Quote