MRC | Criteria | Characteristic |
---|---|---|
ASWT | Intake Connection Thread Size And Series/Type Designator | 0.500-14 NPT AND 1.000-11-1/2 NPT |
AHZA | Pumping Element Operating Position | HORIZONTAL |
AHYV | Maximum Discharge Flow Rate | 42.0 GALLONS PER MINUTE |
AHZT | Operation Method | POWERED |
AAYV | Discharge Connection Quantity | 2 |
AHYZ | Operating Speed At Rated Capacity | 466.7 STROKES PER MINUTE |
AHYW | Discharge Pressure | 125.0 POUNDS PER SQUARE INCH GAGE |
AHYX | Total Head | 289.000 FEET |
AHZJ | Pump Reciprocating Design | DOUBLE ACTING |
AHZQ | Control Location | CENTER |
AAXZ | Cylinder Quantity | 2 |
AHZN | Reciprocating Stroke Type | FIXED |
AHZP | Volume Control Type | PRESSURE COMPENSATION |
MRC | Decoded Requirement | Clear Text Reply |
AAXX | Mounting Type | BASE |
AENG | Pumping Element Type | DIAPHRAGM |
ACKL | Media For Which Designed | HYDROCARBON FUELS AND OILS |
AAYW | Discharge Connection Type | THREADED EXTERNAL AND THREADED INTERNAL |
AGAV | End Item Identification | ONBOARD 400 FT WAGB COAST GUARD VESSELS |
AAYT | Intake Connection Quantity | 2 |
ASAZ | Discharge Connection Thread Size And Series/Type Designator | 0.750-14 NPT AND 1.000-11-1/2 NPT |
AAYU | Intake Connection Type | THREADED INTERNAL |