MRC | Criteria | Characteristic |
---|---|---|
APQB | Unit Type | DIAL INDICATING |
FTLD | Functional Description | USED TO SCAN INSULATED LINES AND CHECK HEAT LEAKS, FOR PRECISE MEASUREMENT IN PLANT MAINTENANCE AND OTHER GENERAL APPLICATIONS; MOST ACCURATE WHEN PRIMARY USE IS ABOVE 600 DEG F (320 DEG C) |
STYL | Style Designator | PORTABLE, HANDHELD |
ATEQ | Scale Type | BROAD ARC DIAL |
FEAT | Special Features | SWITACHABLE DUAL SCALE; READOUT PRECISION TAUT BAND DIAL METER WITH MIRROR SCALES, KNIFE EDGE POINTER, SWITCHABLE DUAL SCALES, 3 INCH SCALE LENGTH,LOW SCALE ONE HALF OF RANGE, HIGH SCALE ONE HALF OF RANGE; SCALE ALSO READS 0 TO 300 DEG C AND 200 TO 600 DEG C; SCALE DIVISION 10 DEG F OR 5 DEG C; SPECTRAL RANGE 4.8 TO 20 MICRONS; ACCURACY 1% FULL SCALE; OPERATION TEMP 35 TO 120 DEG F; REPEATABILITY 0.5%; RESPONSE TIME 1 SECOND; TARGET SIZE 1.6 INCH 0 TO 4 FT; WORKING DISTANCE 0 TO 20 FT; SIGHTING SYSTEM ENCLOSED OPTICAL; ADJUSTABLE EMISSIVITY 0.2 TO 1.0; MANUAL ZERO CALIBRATION BY HALF SQUEEZE DETENT OF THE TRIGGER SHIELD; OUTPUT TO RECORDER 0 TO 1.0 V RESPONSE TIME 0.5 SECOND; INTERNAL POWER 2 BATTERIES 5.4 V, 500 HOUR LIFE |
CSYG | Scale Measurement Range | +0.000/+600.000 DEG FAHRENHEIT AND +500.000/+1100.000 DEG FAHRENHEIT |
CXCY | Part Name Assigned By Controlling Agency | DIAL METER HEAT SPY THERMOMETER |