5930-00-736-8732 Item PartTypeName: SWITCH,ROTARY | 5930 | 007368732 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1470 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.062 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.570 INCHES MAXIMUM |
ABNB | FIRST FLAT LENGTH | 0.560 INCHES NOMINAL SINGLE ACTUATOR |
ABWV | SHAFT DIAMETER | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
ABXF | SHAFT LENGTH | 1.470 INCHES NOMINAL SINGLE ACTUATOR |
AFBH | INDIVIDUAL SECTION QUANTITY | 2 |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.722 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AJZE | SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
AKPX | POLE QUANTITY | 3 EACH SECTION PERIPHERY |
AKPY | THROW QUANTITY | 3 EACH SECTION PERIPHERY |
AXGY | MOUNTING METHOD | BRACKET SINGLE MOUNTING FACILITY |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 118.0 AC AT SEA LEVEL |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION DIAGONAL SINGLE MOUNTING FACILITY |
CRJH | SWITCH ACTUATOR INDEXING POSITION QUANTITY | 3 SINGLE ACTUATOR |
CSCF | TERMINAL TYPE | TURRET |
CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES EACH SECTION PERIPHERY |
CTDN | SWITCH ACTUATOR STOP DEVICE TYPE | FIXED STOP SINGLE ACTUATOR |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL |
FEAT | SPECIAL FEATURES | CROSSTALK SHALL NOT EXCEED 40DB DOWN WITH 2000 OHMS BETWEEN TERMINALS AND GROUND AND A 2V RMS 2 KC SIGNAL APPLIED TO ANY TERMINAL |
STYL | STYLE DESIGNATOR | TAP,SQUARE FRAME |
CRSJ | SHAFT TYPE | ROUND,V FLATTED SINGLE ACTUATOR |