Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-098-9267 Item PartTypeName: FILTER,BAND PASS | 5915 | 010989267 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
TBP-210-7.1-4SS1 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 5.000 INCHES MINIMUM AND 5.500 INCHES MAXIMUM |
ADAR | BODY OUTSIDE DIAMETER | 0.530 INCHES MAXIMUM |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 210.0 MEGAHERTZ SINGLE BAND PASS |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS SINGLE BAND PASS |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS SINGLE BAND PASS |
AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.5 SINGLE BAND PASS |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 CONNECTOR |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 6.0 BLANK |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 CONNECTOR,PLUG INPUT-OUTPUT |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 10.00 MEGAHERTZ BLANK AND 181.00 MEGAHERTZ BLANK AND 239.00 MEGAHERTZ BLANK AND 415.00 MEGAHERTZ BLANK |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 1.50 MEGAHERTZ BLANK |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 60.0 MINIMUM BLANK AND 70.0 MINIMUM BLANK 1ST FUNCTION |
CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | 1.0 MEGAHERTZ SINGLE BAND PASS |
STYL | STYLE DESIGNATOR | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |