Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
ZZZY | Reference Number Differentiating Characteristics | AS DIFFERENTIATED BY THE MATERIAL |
FEAT | Special Features | LOW FLOW RATE MEASUREMENT,READABLE TO 0.5 % OF RANGE, ACCURATE WITHIN 2 % FROM 0.1 PISA TO 250 PSIG, TRANSDUCER COMPLETELY EXTERNAL TO FLOW SYSTEM,SOLID STATE METER CIRCUITRY, NON-LINER,RECORDABLE DC OUTPUT SIGNAL, 0 TO 5000 CC/MIN FLOW RANGE, THERMAL OPERATING TECHNIQUE, TEMP RANGE, UP TO 100 DEG. C, AMBIENT TEMP, 0 TO 40 DEG. C, CALIBRATED FOR AIR ONLY, 115 VOLTS AC, 50/60 CYCLES, 15 WATTS, DIM., 7.75 X 5.75 X 5.75 IN., 0.1 PSIAS TO 250 PSIG OPERATING PRESSURES, UP TO 100 DEG. C FLOW TEMP, AMBIENT TEMP 0 TO 40 DEG. C, 0.5 % FULL SCALE SENSITIVITY, RESPONSE TIME APPROX. 30 SEC., OUTPUT APPROX. 0-3 MILLI V DC INTO HIGH IMPEDENCE, MONEL CONSTRUCTION |
Guaranteed on-time |
|
Customized and |
|
Over 5100 |
|
Complete Purchasing |