5930-00-815-3531 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 008153531 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
J56A80 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
ABHP | OVERALL LENGTH | 4.937 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 1.750 INCHES NOMINAL |
ALAQ | MOUNTING FACILITY CIRCLE RADIUS | 0.625 INCHES NOMINAL |
AXGY | MOUNTING METHOD | FLANGE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQYJ | MOUNTING FACILITY PATTERN | THREE POSITION CIRCULAR |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 200.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 185.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SINGLE VOLTAGE |