NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-120-8426 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 011208426 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
45A0087 | E | 8 | E |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 0.375 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 0.370 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 3.3 KILOHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 TERMINAL SINGLE MOUNTING FACILITY |
CBBL | FEATURES PROVIDED | COIL VOLTAGE SUPPRESSION AND POLARIZED |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 7.9 MILLIAMPERES DC SINGLE WINDING |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CRXH | TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE TIME |
CRXH | TIME DELAY | 0.0075 SECONDS MAXIMUM FIXED RELEASE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 MILLIAMPERES DC LAMP LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
FEAT | SPECIAL FEATURES | FAILURE RATE LEVEL 0.1 PERCENT; 0.500 IN. MINIMUM LEAD LG |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD ALL FUNCTIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/21 GOVERNMENT SPECIFICATION |