Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-595-2373 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015952373 | P | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AP7-1-50-752 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | Body Style | SINGLE POLE TYPE |
ABTD | Mounting Slot Width | 0.130 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES DC SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 7.5 DC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 2 SLOT |
AKPX | Pole Quantity | 1 |
CXCY | Part Name Assigned By Controlling Agency | AP MAGNETIC CIRCUIT BREAKER |
MRC | Decoded Requirement | Clear Text Reply |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 100.0 SINGLE LOCATION |
CPRQ | Reset Method | AUTOMATIC |
ADTV | Case Material | METAL |
AJWX | Mounting Surface To Terminal End Distance | 1.605 INCHES NOMINAL |
ADAQ | Body Length | 1.562 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.875 INCHES NOMINAL |
ABXD | Bushing Length | 0.386 INCHES NOMINAL |
ADAT | Body Width | 1.281 INCHES NOMINAL |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 40.0 MINIMUM AT 100 PCT AND 0.015 MAXIMUM AT 800 PCT SINGLE LOCATION |
TTQY | Terminal Type And Quantity | 2 QUICK DISCONNECT, MALE |
Guaranteed on-time |
|
Customized and |
|
Over 5100 |
|
Complete Purchasing |