Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-969-3282 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 009693282 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Z80304-36 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.906 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.750 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 3.063 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 36.000 INCHES NOMINAL |
AEVU | BULB LENGTH | 3.000 INCHES NOMINAL |
AEVV | BULB DIAMETER | 0.375 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AXGY | MOUNTING METHOD | BRACKET |
CBBL | FEATURES PROVIDED | TUBING END SEAL CONNECTION |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 2 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CTHF | CONTACT LOAD CURRENT RATING | 25.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 35.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | 100.00 TO 550.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL FIRST VOLTAGE |
Guaranteed on-time |
|
Customized and |
|
Over 5100 |
|
Complete Purchasing |