Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-474-9963 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 004749963 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
58124 | C | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.812 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.937 INCHES NOMINAL |
ADAQ | BODY LENGTH | 2.187 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.750 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.250 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 36.0 INCHES NOMINAL |
AEVU | BULB LENGTH | 7.500 INCHES NOMINAL |
AEVV | BULB DIAMETER | 0.187 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AXGY | MOUNTING METHOD | BRACKET |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 TWO CIRCUIT,DOUBLE BREAK/DOUBLE MAKE,BOTH POSITIONS MAINTAINED |
CSCF | TERMINAL TYPE | TAB,SOLDER LUG |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | 140.00/530.00 ACTUATION POINT DEGREES FAHRENHEIT AND 140.00 TO 500.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SHAFT AND EXTERNAL ACTUATION POINT SHAFT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | STYLE DESIGNATOR | RECTANGULAR W/BRACKET |