Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-502-1521 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 015021521 | 0 | N | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
CKB-38-37060 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AGAV | End Item Identification | NEXT GENERATION RADAR (NEXRAD) |
ABHP | Overall Length | 2.406 INCHES MAXIMUM |
CRXH | Time Delay | 0.60 SECONDS MINIMUM ADJUSTABLE RELEASE TIME AND 60.00 SECONDS MAXIMUM ADJUSTABLE RELEASE TIME |
CWAB | Main Contact Maximum Voltage Rating In Volts | 277.0 AC AND 30.0 DC |
CRNG | Nonpile-Up Main Contact Arrangement | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSXF | Operating Voltage Rating And Type At Specified Temp | 24.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
AXHR | Mounting Facility Type And Quantity | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
ABMK | Overall Width | 1.781 INCHES MAXIMUM |
TTQY | Terminal Type And Quantity | 1 STANDARD TUBE BASE ALL FUNCTIONS |
APCN | Coil Quantity | 1 |
CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 10.0 AMPERES DC RESISTIVE LOAD AND 10.0 AMPERES AC RESISTIVE LOAD |
MRC | Decoded Requirement | Clear Text Reply |
AKDX | Winding Quantity | 1 |
APNP | Duty Type | CONTINUOUS |
ABKW | Overall Height | 2.937 INCHES MAXIMUM |
Guaranteed on-time |
|
Customized and |
|
Over 5100 |
|
Complete Purchasing |