Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
CXCY | Part Name Assigned By Controlling Agency | MEDIUM PRESSURE INLINE FILTER - AGS SERIES |
CQGM | Maximum Operating Pressure | 1000.0 POUNDS PER SQUARE INCH |
ADNH | Filtration Rating In Microns | 10.0 ABSOLUTE |
ADAU | Body Height | 13.100 INCHES NOMINAL |
ADAQ | Body Length | 4.210 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
AGAV | End Item Identification | ABLTS HYDRAULIC SYSTEM |
FEAT | Special Features | HOUSING MATERIAL: HEAD,CAST ALUMINUM; BOWL, ALUMINUM IMPACT EXTRUSION; RING, CAST GRAY IRON; SEALS, NITRILE, STANDARD, VITON; RATED STATIC PRESSURE: 1500PSI; BURST PRESSURE: 3000PSI; RATED FATIGUE PRESSURE: 0-750-0PSI; BYPASS VALVE SETTING: 22PSID; WEIGHT: 5.7LBS; ELECTRICAL RATING: 120 VAC MAX, .5 AMPMAX, CONTACT RATING 10WATTS-MAX; FLOWS TO 25GPM; DISPOSABLE ELEMENT; PORTS: SAE16(15/16-12), MOUNTING HOLES 7/16-14 UNC; AGS FILTER CAN BE MOUNTED TWO WAYS: 1)MOUNTED AS AN INTEGRAL PART OF THE PIPING SYSTEM W/O BRACKET, 2)MOUNTED TO A BRACKET BY MEANS OF FOUR BOLTS FITTED IN THE HEAD; IN BOTH SITUATIONS, NECESSARY TO MOUNT FILTER IN A VERTICAL POSITION |
AZKQ | Temp Rating | -40.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
STYL | Style Designator | STRAIGHT FLOW BASKET STRAINER W/ BOLTED COVER |