5905-01-187-1888 Item PartTypeName: RESISTORVARIABLENONWIRE WOUND | 5905 | 011871888 | 0 | N | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1481-32-2 | 5 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR W/TAB/FLANGE MOUNTED |
AASA | THREAD LENGTH | 0.500 INCHES NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | 0.136 INCHES NOMINAL |
ABWV | SHAFT DIAMETER | 0.112 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 0.625 INCHES NOMINAL |
ADAQ | BODY LENGTH | 5.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.625 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.500 INCHES NOMINAL |
AEDX | SHAFT STYLE | ROUND,THREADED |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AFQM | DISTANCE BETWEEN MOUNTING HOLE CENTERS | 0.375 INCHES NOMINAL |
AGTP | LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS | 5.250 INCHES NOMINAL |
AKPV | MOUNTING FACILITY QUANTITY | 4 |
APXH | UNABLE TO DECODE | UNABLE TO DECODE |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 10.000 KILOHMS SINGLE SECTION |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
CQTM | TERMINAL LOCATION | REAR END |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 6.0 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |