NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5970-00-263-1351 Item PartTypeName: INSULATION SLEEVING,ELECTRICAL | 5970 | 002631351 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
GMS5-13-09-0 | 3 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAGT | WALL THICKNESS | 0.013 INCHES MINIMUM AND 0.019 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AARX | INSIDE DIAMETER | 0.064 INCHES MINIMUM AND 0.072 INCHES MAXIMUM |
ABJH | TEMP RATING | -30.0 DEG CELSIUS AND 75.0 DEG CELSIUS |
ADZC | ENVIRONMENTAL PROTECTION | FLAME RESISTANT AND MILDEW RESISTANT AND OIL RESISTANT |
CQBC | MINIMUM TENSILE STRENGTH | 1800 POUNDS PER SQUARE INCH |
FLEX | FLEXIBILITY | FLEXIBLE |
HUES | COLOR | BLACK |
MATL | UNABLE TO DECODE | UNABLE TO DECODE |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 800.0 VOLTS PER MIL 0.001 INCH |
ZZZT | NONDEFINITIVE SPEC/STD DATA | 1 CATEGORY AND I CLASS AND U FORM AND A GRADE AND 14AWG SIZE AND UA SUBFORM AND F TYPE |
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MOD BY COLOR |