MRC | Criteria | Characteristic |
---|---|---|
FUEL | Fuel Type | DF-A ARCTIC DIESEL FUEL OIL OR DF-1 WINTER DIESEL FUEL OIL OR DF-2 REGULAR DIESEL FUEL OIL OR JP-5 JET FUEL OR KEROSENE OR SOLID FUEL |
ABGL | Width | 9.000 INCHES NOMINAL |
FEAT | Special Features | OPTIONAL ITEMS ORDERED SEPARATELY,FUEL CAN STAND,COLLAPSIBLE 4520-01-465-4430,FUEL HOSE KIT 4520-01-466-0420,GRAVITY FED KIT 4520-01-466-0415,FUEL CONTROL VALVE 4520-01-466-0409FEATGEND APPLICATION:GENERAL PURPOSE USE UB 5 AND 10 MAN ARCTIC TENTS,THIS IS A DIRECT REPLACEMENT FOR THE OLD M1950 YUKON STOVE;OPTIONAL ITEMS ORDERED SEPARATELY FUEL CAN STAND,COLLAPSIBLE 4520-01-465-4430,FUEL HOSE KIT 4520-01-466-0420,GRAVITY FED KIT 4520-01-466-0415,FUEL CONTROL VALVE 4520-01-466-0409. THE SPACE HEATER ARCTIC (SHA) IS LIGHTWEIGHT, PORTABE, MULTIFUELED, NON-POWERED HEATER. SEE ARMY OPERATOR'S MANUAL TM 10-4520-261-12 AND P. |
BLJC | Ignition Method | MANUAL |
BDXJ | Heating Element Type | BURNER |
ABAM | Heat Medium Type | AIR |
HGTH | Height | 17.000 INCHES NOMINAL |
AAXX | Mounting Type | FLOOR SURFACE, FREE STANDING, NONDUCTED |
AGAV | End Item Identification | GENERAL PURPOSE USE IN 5 AND 10 MAN ARCTIC TENTS THIS IS A DIRECT REPLACEMENT FOR THE OLD M1950 YUKON STOVE |
MRC | Decoded Requirement | Clear Text Reply |
ABMZ | Diameter | 17.500 INCHES NOMINAL |
ALYC | Operating Control Type | HAND SWITCH |
CSGC | Fuel Feed Method | GRAVITY |
ABBE | Circulated Air Type | HEATED |
CQXD | Heat Delivery Rate | 27000.0 BRITISH THERMAL UNIT |