Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
ACSY | Furnished Items And Quantity | 1 MOTOR CONTROLLER |
ELEC | Voltage In Volts | 230 |
AKPS | Duty Cycle | INTERMITTENT |
ADZC | Environmental Protection | WATERTIGHT |
ATWD | Drum Flange To Flange Distance And Location | 18.000 INCHES NOMINAL FIRST DRUM |
ATWN | Load Limit At Selected Speed And Drum Location | 9350.0 POUNDS SINGLE SPEED SECOND DRUM |
ATWE | Drum Diameter And Location | 19.500 INCHES NOMINAL FIRST DRUM |
ATWE | Drum Diameter And Location | 19.500 INCHES NOMINAL SECOND DRUM |
AWFA | Drum Designation | LEFT-HAND |
ATWS | Braking Method | ELECTRIC |
ATYG | Power Requirement Rating | 12.50 HORSEPOWER |
ACDC | Current Type | DC |
BFMF | Cooling Method | ANY ACCEPTABLE |
ATWD | Drum Flange To Flange Distance And Location | 18.000 INCHES NOMINAL SECOND DRUM |
ATWN | Load Limit At Selected Speed And Drum Location | 9350.0 POUNDS SINGLE SPEED FIRST DRUM |
ATWP | Travel Rate Per Minute | 20.0 FEET |
ATYH | Drum Surface Design | GROOVED |
ZZZY | Reference Number Differentiating Characteristics | AS DIFFERENTIATED BY GENERAL ELECTRIC MOTOR DWG NO. L-8435255,CONTROL PANEL DWG NO. E-8690413 AND MASTER SWITCH DWG NO. L-6922262 |
AAXH | Prime Mover Quantity | 1 |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
MRC | Decoded Requirement | Clear Text Reply |
APHE | Operation Method | POWER |
AKNA | Inclosure Type | FULLY INCLOSED |
Guaranteed on-time |
|
Customized and |
|
Over 5100 |
|