Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-406-2867 Item Description: Circuit Breaker | 5925 | 014062867 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ce3-G3-Ab0030-01b | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 105.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.750 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC ALL LOCATIONS |
AJEC | Boss Height | 0.219 INCHES NOMINAL |
AKPX | Pole Quantity | 3 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.026 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPRY | External Actuator Linkage Arrangement | ONE AND TWO LINKED |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
ADAT | Body Width | 3.138 INCHES NOMINAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.609 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 5.800 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 4.750 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
TTQY | Terminal Type And Quantity | 6 COMPRESSION |
MRC | Decoded Requirement | Clear Text Reply |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.026 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 460.0 AC ALL LOCATIONS |
THSD | Thread Series Designator | UNC |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 50.000 MINIMUM AT 200 PCT AND |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |
Guaranteed on-time |
|
Customized and |
|
Over 5100 |
|
Complete Purchasing |