5930-01-200-7881 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 012007881 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
P49/100/040 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT AND HUMIDITY RESISTANT AND VIBRATION RESISTANT |
ABHP | OVERALL LENGTH | 2.680 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 1.380 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.070 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.218 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.740 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.220 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 24.00 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE |
AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET AND SLOT AND UNTHREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CSCF | TERMINAL TYPE | QUICK DISCONNECT,MALE |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 27.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 35.50 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | STYLE DESIGNATOR | RECTANGULAR |