Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
AHYV | Maximum Discharge Flow Rate | 7900.0 GALLONS PER MINUTE |
ELEC | Voltage In Volts | 440 |
AHZE | Centrifugal Pump Design | MIXED FLOW |
AHYZ | Operating Speed At Rated Capacity | 1200.0 REVOLUTIONS PER MINUTE |
AHZA | Pumping Element Operating Position | VERTICAL |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
ACDC | Current Type | AC |
FREQ | Frequency In Hertz | 60 |
AAXH | Prime Mover Quantity | 1 |
FAAZ | Phase | THREE |
CSYL | Prime Mover Power Rating | 200.000 HORSEPOWER |
MRC | Decoded Requirement | Clear Text Reply |
AENC | Pump Quantity | 1 |
ZZZY | Reference Number Differentiating Characteristics | AS DIFFERENTIATED BY PRIME MOVER TYPE REQUIREMENT,ELECTRIC MOTOR MFR GENERAL DYNAMICS CORP ELECTRO DYNAMICS DIV AVENEL OPERATIONS DWG NO. 3586-1 |
AMPS | Current Rating In Amps | 244.2 |
ACKL | Media For Which Designed | WATER, SALT |