Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-325-7488 Item PartTypeName: FILTER,RADIO FREQUENCY INTERFERE | 5915 | 013257488 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1ED1 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AGAV | END ITEM IDENTIFICATION | 5895-01-316-2747 CENTRAL,COMMUNICATIONS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AKNA | INCLOSURE TYPE | ENCASED |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR,RECEPTACLE INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB,SOLDER LUG OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
ADAQ | BODY LENGTH | 1.190 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.810 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.132 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.575 INCHES NOMINAL |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 1ST RADIO INTERFERENCE |
CQRG | BODY MATERIAL | METAL |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 2ND RADIO INTERFERENCE |
ABHP | OVERALL LENGTH | 1.980 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 2.200 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.950 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 50.0 1ST RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 50.0 2ND RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | MOUNTING BRACKET |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB,SOLDER LUG GROUND 3RD FUNCTION |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 2.25 KILOVOLTS AT SEA LEVEL |
FEAT | SPECIAL FEATURES | TWO FILTERED FUNCTIONS |
Guaranteed on-time |
|
Customized and |
|
Over 5100 |
|
Complete Purchasing |