Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
ACSY | Furnished Items And Quantity | 1 MOTOR CONTROLLER AND 1 PAY OUT MECHANISM |
ELEC | Voltage In Volts | 440 |
AKPS | Duty Cycle | INTERMITTENT |
ADZC | Environmental Protection | SPLASHTIGHT |
ATWD | Drum Flange To Flange Distance And Location | 8.500 INCHES NOMINAL FIRST DRUM |
ATWN | Load Limit At Selected Speed And Drum Location | 2000.0 POUNDS SINGLE SPEED FIRST DRUM |
FAAZ | Phase | THREE |
ATWE | Drum Diameter And Location | 9.500 INCHES NOMINAL FIRST DRUM |
ATWE | Drum Diameter And Location | 9.500 INCHES NOMINAL SECOND DRUM |
AWFA | Drum Designation | RIGHT-HAND |
ATWS | Braking Method | MANUAL |
ATYG | Power Requirement Rating | 13.50 HORSEPOWER |
ACDC | Current Type | AC |
BFMF | Cooling Method | ANY ACCEPTABLE |
MRC | Decoded Requirement | Clear Text Reply |
ATWD | Drum Flange To Flange Distance And Location | 8.500 INCHES NOMINAL SECOND DRUM |
ATWN | Load Limit At Selected Speed And Drum Location | 2000.0 POUNDS SINGLE SPEED SECOND DRUM |
ATWP | Travel Rate Per Minute | 80.0 FEET |
FREQ | Frequency In Hertz | 60 |
ATYH | Drum Surface Design | PLAIN |
AAXH | Prime Mover Quantity | 1 |
FEAT | Special Features | NONMAGNETIC CONSTRUCTION |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
APHE | Operation Method | POWER |
AKNA | Inclosure Type | FULLY INCLOSED |
Guaranteed on-time |
|
Customized and |
|
Over 5100 |
|
Complete Purchasing |